Rated Voltage35kVBelow Medium Voltage XLPE In |
|
It is suitable for rated voltage 35kV and below circuit for transmission and distribution. XLPE power cable has excellent electrical properties and heat resistance. Compared with oil-filled cable, it has no leakage problem, no drop restrictions on laying and can be major laying.
Rated Voltage35kVBelow Medium Voltage XLPE Insulated Power Cable:
1)XLPE Insulated PVC Jacketed Power Cable Its conductor uses standard copper or aluminum conductor. It uses three layers cross-linking equipment for conductor shield, insulation and insulation shield. It uses extruded-type shield layer for conductor shield, ultra-clean cross-linked PE material for insulation, and extruded-type shield layer for insulation and shield layer. Shielded structure was used in insulated core with conductor cross-section below 500mm2. The thickness of three-core copper cable is 0.10mm. The wire cores shielded by three copper belts are stranded to one cable through semi test and cabling procedure. Its outer jacket use PVC material.

2)XLPE Insulated Steel Belt Armored PVC Jacketed Power Cable Its conductor uses standard copper or aluminum conductor. It uses three layers cross-linking equipment for conductor shield, insulation and insulation shield. It uses extruded-type shield layer for conductor shield, ultra-clean cross-linked PE material for insulation, and extruded-type shield layer for insulation and shield layer. Shielded structure was used in insulated core with conductor cross-section below 500mm2. The thickness of three-core copper cable is 0.10mm. The wire cores shielded by three copper belts are stranded to one cable through semi test and cabling procedure. Its inner jacket use PVC or PE material (upon request). It is armored with galvanized steel. Its outer jacket use PVC material.

3)XLPE Insulated Thin Steel Wire Armored PVC Jacketed Power Cable Its conductor uses standard copper or aluminum conductor. It uses three layers cross-linking equipment for conductor shield, insulation and insulation shield. It uses extruded-type shield layer for conductor shield, ultra-clean cross-linked PE material for insulation, and extruded-type shield layer for insulation and shield layer. Shielded structure was used in insulated core with conductor cross-section below 500mm2. The thickness of three-core copper cable is 0.10mm. The wire cores shielded by three copper belts are stranded to one cable through semi test and cabling procedure. Its inner jacket use PVC or PE material (upon request). It is armored with thin steel wire. Its outer jacket use PVC material.
 |
|
|
|
|